ElectronicsDIY5 web shop weblog

電子工作関連(組み込みシステム、アマチュア無線、測定器自作など)の商品に関して、紹介と補足説明をします。

Siglent a free EMI option activation license offer

2022-05-16 18:41:01 | スペアナ

Siglent a free EMI option activation license offer

****************************************

ElectronicsDIY5 web shop

www.shop-online.jp/ElectronicsDIY5/

*****************************************

Purchase any SIGLENT spectrum analyzer and SRF5030T near-field probe kit* and receive a free EMI option activation license!

https://int.siglent.com/info/detail-57.html

**********************************************

上記のEMI option activation licenseの無償供与は、

下記のlinkのいずれかの SIGLENT spectrum analyzerを新しく購入し、

https://int.siglent.com/products/spectrum_analyzers/

且つ。

SRF5030T near-field probe kit

https://int.siglent.com/article/detail-517.html

を同時購入した場合に

EMI option activation license!

を無償で提供するキャンペーンです。

sales manageniに確認しましたが、すでに、Siglent スペアナを持っていて、SRF5030Tを購入する条件には適応されないそうです。

https://int.siglent.com/info/detail-57.html

 


A New Bundle for EMI pre-compliance test 

2022-03-31 14:46:11 | スペアナ

A New Bundle for EMI pre-compliance test 

(2022-01-14 記載)

https://int.siglent.com/info/detail-40.html

*****************************************

ElectronicsDIY5 web shop

www.shop-online.jp/ElectronicsDIY5/

*****************************************

(2022-03-31) 更新

https://int.siglent.com/info/detail-40.html

は、3/31を持って、discontinueになりました。

その他のpromotionは、以下でご確認の上、当方にお問合せ下さい。

https://int.siglent.com/info/promotions

 


1.5GHzスペアナ/トラジェネ OWON XSA1015-TG  起動できなくなる不具合について

2021-12-02 16:24:34 | スペアナ

1.5GHzスペアナ/トラジェネ OWON XSA1015-TG  Spectrum Analyzer /Tracking Generator

起動できなくなる不具合について

修理例 main boardの交換

*****************************************

ElectronicsDIY5 web shop

www.shop-online.jp/ElectronicsDIY5/

*****************************************

XSA1015-TGが、起動できなくなる不具合について、例をあげて、説明しますが、XSA1032-TG/XSA1036-TG/XSA1075/XSA1075-TGでも同じですので、参考にしてください。

起動できなくなった場合は、なんらかの故障です。それが、hardwareが故障しなくても、起動不良は起こりえます。なにか、測定している途中で、その測定のせいで、故障したのではないかと思う場合は、極力、申告しておいたほうがいいです。そのほか、なにも心当たりがなくても、数か月振りに起動させようとすると、起動しないこともあり得るようです。AC100V 50Hz/60HzのACケーブルは、できれば、コンセントのLive/Neutralを意識した接続が本来、望ましいです。きちんと、工事されていれば、延長ケーブルのコンセントに3PIN 電源ケーブルで接続する意味がでてきます。どうも、Live/Neutralを意識した接続でないがために、スペアナ本体にショックを与え、firmwareがdeteriorateしたのかもと思わせる起動不良がある可能性もある様です。また、長時間、測定する場合は、電動パッドだけでもいいので、スペアナ本体のアースと接続することも考慮下さい。

実際、起動できなくなっても、それを送り返さずに、firmwareの再書き込みができて、正常起動回復できる場合があります。当方では、これで、まず対処して、それでだめなら、ビデオを撮ってもらって、それを、OWON sales managerに見せます。ビデオは、sales managerが、engineersに見せて、中国語で説明するために必要で、実際、向こうから、ビデオ撮影を要求されるので、不具合の場合は、youtubeにuploadして、unlistedでむこうに確認してもらいます。一般に中国では、youtubeは音声のみとか、動画、音声もみることができないので、他の企業に依頼して見ることができるそうで、これは、一般には、個人購入では、ビデオを海外販売者に見せることができないのが、3年保証で無償修理ができない原因の一つです。不具合のビデオは当方に、ストレージにuploadして、当方がdownloadするか、youtubeにunlistedでuploadしてもらえれば、こちらで、downloadします。(メールで20MBに圧縮して、送るかたがいますが、それは画質も悪いですし、本来、非常識ですので、やらないで下さい)

XSA1015-TGが、起動不良になった場合、いくつかの違う症例があります。まず、AC100Vrmsを印加して、一瞬、LCD displayが、ぴかっと光るのはいい傾向です。まず、back lightの故障は否定されます。次に、power on switchを押して、しばらくすると画面が白いロゴの画面が現れて、このロゴの状態で、そのまま、止まってしまい、正常起動が完了しないのが一番、よく見られる現象で、この起動不良で、hardware自体に問題ない場合は、firmwareがなんらかのショックでdeteriorateした場合であれば、firmwareの書き込みモードに入って、re-configurationを試み、正常起動ができます。逆に、これで、正常起動できなければ、なんらかのhardware故障です。power onで、白い画面のロゴが出てくれば、途中でとまっても、予後がいい場合があります。

power onで、白い画面のロゴも現れないと、black lightがほんとうに大丈夫かは、100% ruled outできませんが、power onで、一瞬、LCDがぴかっと光る場合は、少なくとも、main boardの交換で修理ができましたので、LCD displayのほうは問題ない場合がありました。

firmwareのre-configurationが成功しない場合、いつまでも、黒いままであっても、必ずしもback light故障とは言えません。そういう場合も、main boardの交換で修理できた例はあります。

3年保証期間の場合、基本的には、当方では,まずは、main boardに交換で対応します。main boardの交換は、今までの例では、すべて、main boardをOWONから、そちらへ、無償で送った場合、suspectedされたように、main boardの交換で修理が完了しています。power onでロゴがでてくる場合はこれでいいのですが、問題は、power onでロゴもでてこないときです。この場合は、本体を送り返さずにmain board交換で修復できた場合もあり、使用者の予期せぬこと(RF samplerで、1kWリニアアンプを接続して、スプリアス測定時に突然、ブレーカーが落ちた)で、main board以外に、power supplyも故障して、本体を送り返して、両基板交換に至る場合もありました。(この場合は、本来、3年故障に該当しない、2つの基板の故障でしたが、修理自体は無償で、送り返す送料だけは負担してもらいました。前もって、故障原因に思い当たる場合は申告頂くと3年保証以外の故障でも修理自体は、無償になる例はありましたが、いつも、そうではないとは思います。ですので、入力でoverloadさせたとか、使用者責任の故障が疑われる場合は、前もって、言ってもらったほうがいいと思います。突然、ブレーカーが落ちた例では、購入者の方がかなり詳しい事情の説明と画像を送ってくれたので、当方のほうでも事情を英語で説明したので、無償修理してくれたと思います。事情があれば、説明してくれたほうがいいと思います)

人によっては、電源ラインの電圧測定もできれば、それに越したことはありません。基板の動作電圧は、約5.5V DCです。

実際、起動不良が起これば、メールをしてください。その時、購入情報を記載して、できれば、納品書のコピーを添付下さい。

main boardの交換で済みそうな場合は、はじめから、そちらへ、無償で送る場合もあります。main boardの交換は困難でなく、参考画像は提供しますが、無理と思う方には、当方が行う場合もありますので、お問合せください。

(3年以上経過した、3年保証外の故障について)

3年以上、経過した、不具合にも対応しますが、有償になります。前もって、どこが壊れているか、わからない時点で、修理費はわからない点はご理解ください。

********************************************************

1.5GHzスペアナ/トラジェネ OWON XSA1015-TG  Spectrum Analyzer /Tracking Generator

https://blog.goo.ne.jp/electronics_diy_5/e/47b6dd1478544149625c30ee06b643bf

********************************************************

(当方から、OWON製スペアナを購入したほうがいい理由)

スペアナでは、HSA1016-TGなどの、HSA1000 Seriesも、起動できなくなった場合の最初の対応として、firmwareのre-configurationで対処可能です。(XSA800 Seriesも、XSA1000TG Series同様に対処可能です。

HSA1016-TGでは、ケーブルテレビのチャンネル パワー(channel power)は、伝統的に、dBuVと、spectral power densityで結果表示しないといけないですが、これに対応した例は、今のところ、購入者のHSA1016と当方のHSA1016-TGのみで、XSA800 Series,XSA1015-TGは、channel power は、dBm表示です。Keysightも単位は、dBmで、ケーブルテレビ専用のスペアナのみが、仕様変更されています。基本、すくなくとも、HSA1016は、ケーブルテレビ 測定使用のchannel power測定仕様に改変可能です。


New Model OWON Spectrum Analyzer/XSA800 Series

2021-10-11 16:59:28 | スペアナ

New Model 

OWON Spectrum Analyzer

XSA800 Series

Product review in English

*****************************************

ElectronicsDIY5 web shop

www.shop-online.jp/ElectronicsDIY5/

*****************************************

XSA800 Series Spectrum Analyzer

https://www.owon.com.hk/products_xsa800_series_spectrum_analyzer

OWON XSA800 Spectrum Analyzer Introduction

https://www.youtube.com/watch?v=Sgv3jXLYUVo

I got XSA815-TG as demo,and almost I finish evaluating it.

The performance is mostly what I expected,and also I am satisfied with total capability.

I'd like to introduce XSA815-TG to the all over the world for the first time ever.

**************************************************

First of all,look at that youtube video.It is not FFT mode,but Swept-Tuned Mode!!

Waveform refresh rate is like HackRF ONE(which is working with FFT mode,and Bin width is probably some extent broad,instead XSA815-TG is working with swept-tuned mode,because RBW is 100kHz at this measurement)

NEXT! 700MHz Smartphone downlink/OWON New Spectrum Analyzer XSA815-TG

https://www.youtube.com/watch?v=OHFdFKEuM8I

Actually faster than HSA1016-TG!!

***************************************

Talking about the specification is like below.There are 6 models releasing.XSA805 and XSA805-TG are 500MHz models,XSA810 and XSA810-TG  are 1GHz models,and XSA815 and XSA815-TG are 1.5GHz models.

I think,someone might think,what is the difference,compared to XSA1000TG Series.LOL

As you know,XSA1000TG Series are 3 models ,XSA1015-TG,XSA1032-TG,and XSA1036-TG.

https://www.owon.com.hk/products_xsa1000tg_series_spectrum_analyzer

(1)LCD Display Size

XSA815-TG 9inch/XSA1015-TG 10.2inch.(Size itself XSA1015-TG is bigger than XSA815-TG)

(2)The port for the external LCD Display

XSA815-TG  with HDMI/XSA1015-TG with VGA

(3)XSA815-TG works wth 2 mode,Swept-Tuned Mode and FFT mode.(Now the information is limited,only available "Quick Guide",so I don't know the details yet,but according to this guide,"When RBW is set to less than 3kHz,automatically switch to FFT mode)Just I know,when I try to use max hold mode,less than RBW 3kHz,plotting is so precise.Plz wait for the additional information.I don't recognize  downsides  at the moment.

(4)Tracking Generator's specification is not same as one of XSA1015-TG.Once first time,when we try to do normalization,the initial setting RBW/VBW is set to 30kHz,but after that,you can change RBW/VBW up to 3kHz,then you can do normalization again.It seems works fine.

(5)XSA815-TG has the quasi-peak detector and EMI filter's RBW set-up,as same as XSA1015-TG.(As you know,Siglent and RIGOL Spectrum Analyzer,it is the option as EMI)

(6)XSA815-TG has also so-called Advanced Measurement Kit(AMK) like ACPR,Channel Power,OBW etc,as same as XSA1015-TG.(As you know,Siglent and RIGOL Spectrum Analyzer,it is the option as AMK)

(7)XSA815-TG can do measure the noise power(dBm/Hz),as same as XSA1015-TG.

*************************************************

XSA815-TG has HDMI port,and I confirmed working well even with 32inch LCD Display.

XSA815-TG Initial Test

https://www.youtube.com/watch?v=RuskjHOpuFc

XSA815-TG can do screen capture into the internal storage or USB Flash memory.

XDG3252(250MHz model) with the external reference (GPS Desciplined)/Sine Wave 10.000000000MHz(up to 1x10E9 set-up available)

When you hope to save all screen picture,including right column,at first insert USB Flash Memory,then plz push "Quick Save" like below.(Otherwise,also you can save from "Save/Recall" like other screen pictures.

Push on "Peak",then you get the actual measuring frequency,just 7.100000MHz (w/Extesrnal reference 10MHz,frequency offset 0Hz at span 1kHz)

Reference Extenal(if working for long time,no need frequency offsets)

Reference Internal(if working for long time,no need frequency offsets)

I confirmed PC Software is already available.

You can easily measure the higher harmonics of Anritsu SSG MG3601A.Such a case,using the Marker Table is convenient.

You can do measure so-called noise power(dBm/Hz),and you can predict the phase noise//10kHz offset is <-80dBc/Hz sure.

Now I get prepared for measuring Home-Made 7MHz BPF(center frequency 7.1MHz/BW 100kHz,-3dB or 138kHz -6dB/insertion loss around -5.5dB) with the Tracking Generator!!

Actually it is for my homebrew software defined radiot(SDR) transceiver and home-made FPGA-Based  SDR.and also softrock group SDRs.

3dB Bandwidth,we can use the marker function as NdB 3.0     3dB BW is measured as 99.5kHz

You can also measure 6dB BW with the markers setting,using delta.   6dB BW is measured as 138kHz

**************************************************

You can monitor the sweep signals like below.>>>Not so bad,isn't it?(Here in my shack/Radio Room,sorry for messy situation,my appology)

Measuring the sweep signal of OWON XDG3252 with OWON XSA815-TG

https://www.youtube.com/watch?v=BK-ZqrnCmX4

Signal source::OWON XDG3252  6.9MHz-7.3MHz -10dBm/sweep time 1 second

Setting of XSA815-TG(Trigger Auto Run)
(1)Frequency: Start 6.8MHz/Stop 7.4MHz
(2)SPAN 600KHz
(3)Center 7.1MHz
(4)RBW 5kHz/VBW 5kHz(Non FFT mode)
(5)Detector: Positive Peak
(6)Sweep Time 134.4ms
(7)TRACE:Max Hold

**************************************************

For the case that If you don't purchase TG model like XSA805/XSA810/XSA815

You can also measure BPF without TG precisely.

Scalar Measurement of 7MHzBPF/OWON XDG3252 with OWON XSA815-TG

https://www.youtube.com/watch?v=sg5uUa3TfoI

Above youtube video,the typical traditional way of measuring the band pass filter(BPF),if you don't have the tracking generator.

You know,this 7MHz BPF is for the software defined radio/direct conversion type like softrock group etc.If you hope to add the pre-amplifier 20dB,you also have to equip 7MHz BPF,-3dB bandwidth 100kHz to the front end.

7MHz BPF/6dB bandwidth 138kHz(3dB BW is around 100kHz)

Even if you purchase like XSA805,cheapest model.you can somehow measure BPF,the measurement result is almost same as the result with the tracking generator.

*******************************************

I did test FM demodulation.Setting it up properly is so diificult,taking time a lot.LOL

FM demodulation of XSA815-TG/Wide FM

https://www.youtube.com/watch?v=9LQW9STqJWM

*************************************************

One of the upsides of XSA815-TG,which has so-called the advance measurement kit(AMK),it means it is not option like RIGOL and Siglent spectrum analyzer.

Time Spec//OWON calls it as Time Spec(in other words,waterfall,panafall something like that)

ACPR

Channel Power

OBW

Pass Fail

Also XSA815-TG has EMI(Quasi-Peak Detector/EMI Filter),which is not option like RIGOL and Siglent Spectrum Analyzer.


OWONスペアナ XSA1000 Series/XSA800 Series/HSA1000 Series のCSV data save

2021-07-23 12:37:11 | スペアナ

OWONスペアナ XSA1000 Series/XSA800 Series/HSA1000 Series のCSV data save

**********************************

ElectronicsDIY5 web shop

http://www.shop-online.jp/ElectronicsDIY5/

**********************************

OWON スペアナでは、本体項目に明示的に、saveにCSVの項目はないですが、CSV保存を本体表示項目 TRACEでsaveすることが可能です。デジタルオシロでは、どのメーカーもCSVが項目にありますし、Siglent SSA3000X Plus Seriesでは、CSV項目の表示があり、明示的ですが、OWONでは、TRACEの項目で、CSV data保存をします。少なくとも、Excelでは、展開できます。

また、PC spectrum softwareでは、saveは、PNG saveと、CSV saveが選択可能です。

InternalにTRACE saveした、CSV fileは、本体screenにLoadして、波形画面表示が可能です。(通常は、Windows PCでもscreen capture画面表示ができるように、PNGで、data saveするのでいいかとは思います)

デジタルオシロでは、binaryで、saveして、loadで本体波形表示する(Micsigなど)ものや、CSVでdata saveして、loadで波形表示するものがあったり、機種に因ります。OWONスペアナでは、binaryでのsave機能はないです。

今回、今後、Windows PCでのCSV Viewerを開発してほしいとは、R&Dに言っています。

それと、PC softwareでの波形表示とPNG save/CSV save以外に、data logger機能の追加も希望していることを言っています。