How to set up EDIABAS using ENET Ethernet connection

2018-07-27 10:19:48 | 日記




Here’s the instructions for operating BMW Diagnostic Tool EDIABAS software applications under use the ENET cable Ethernet connection.



Version 1.01
Connection EDIABAS and ZGW:
Hardware requirements:
– EthernetCard (RT45)
– ZGW (Central Gateway)
– Patch cable (standard network cable with 1: 1 connection)
ZGW controls the “Autosense” function, i.e., CROSSOVER_cable is possible, but not
necessary.
(Minimum cable requirement: technical spec. Of a CAT5 cable must be fulfilled)



Free download BMW INPA F xx & EDIABAS



Please note :
Settings in Ediabas.ini:
Interface = ENET /(also Proxy: ENET is possible // / under no circumstances: = STD:ENET)
;XETHERNET Configuration
[XEthernet]
RemoteHost = Autodetect->> For a direct connection (option 1)
or
RemoteHost = <IP-Adresse des ZGW>->>When connecting to a DHCP server (option 2)
DiagnosticPort = 6801
ControlPort = 6811
TimeoutConnect = 20000
TesterAddress = F4,F5
HeaderFormat = 0



13-00
13-0
Option 1: direct connection to the PC
The ZGW is connected directly to the computer (no DHCP server).
No IP address may be assigned to the computer (obtain IP address automatically).
“RemoteHost = Autodetect” in Ediabas.ini (see above)
After a short time, XP reports limited connectivity on the network port.



13-000



This message can be ignored.
Communication with the ZGW is now possible via EDIABAS.



With the tool “ZGW_SEARCH.exe” (can be found under “EDIABAS \ Hardware \ ENET”) it is possible the current network parameters of the CGU (see also (*) under option 2).



Option 2: Connection via a DHCP router
The ZGW and the PC must be in the same number range.
With the tool ZGW_SEARCH.exe the current IP address of the ZGW can be determined.
EDIABAS must be closed.
Activate ZGW_SEARCH.exe u. Press “refresh”: it should be followed by the info window with the
IP address filled, appear.



13-1



If the recognition does not succeed, it helps to connect the ZGW directly to the computer (as under
Option 1 described) and let the detection run.



Then connect the ZGW back to the network (ZGW_SEARCH is still active / do not quit!) And
press the button <refresh> again.



The current IP address will now be displayed.



In the Ediabas.ini the current IP address must be entered (can be, in case of longer separation
from the network, change).



Communication with the ZGW is now possible via EDIABAS.



(*) “Tool ZGW_SEARCH.exe” can be found under “EDIABAS \ Hardware \ ENET”.
To work properly with the ZGW_SEARCH.exe tool, it is necessary to have a
“MSWINSCK.OCX” file installed on the same LW in the same folder as ZGW_SEARCH.exe
is.



Network Connection Details:
* Mac address (physical addr .: 00-16-35-A3-E3-AF), explanation
* IP address, for example: 10.253.117.126, explanation, Ω
* subnet mask, for example: 255.255.0.0, explanation
* Default gateway, for example: 10.253.117.8, Explanation, Ω
* DNS server, for example: 160.50.250.8, explanation
* host name, for example: WMUC247843, explanation, Ω
* DHCP server for example: …, explanation



Ω: Addresses / names must be unique



Checking network connections:
Go to Control Panel-> network connections



13-2



Network Connections



13-3



The LAN connection appears, right-click on LAN_connection – Actions window
opens
then click Properties – the following window “Properties of LAN connection” opens.



13-4
1) Internet Protocol (TCP / IP) must be checked and be selected



2) Press the button:
Properties of Internet Protocol (TCP / IP)
Opens (see below)



13-5



IP address automatic Respectively:
Must be selected



13-6



Auto-assigned, private IP address:
Must be selected



Furthermore, a connection test can be carried out by means of “An-Pingen”:
1) Open DOS window: go to “START” >> “click on execute” >> enter “cmd” >> OK.



13-7



2) DOS_ window is open:
3) Behind C: \ Documents and Settings \ Q ……> ping and IP address or host name of the ZGW
enter – confirm with “Return”.



13-8



The positive connection test looks like shown above.



This is just proof that there is a physical / electrical connection.
Of crucial importance are and remain, starting at the beginning of the document,
illustrated setting / connection parameters.



Known handling error messages:
Error 1: Required dll file “MSWINSCK.OCX” is missing.



13-9



The “MSWINSCK.OCX” must be in the same folder as “ZGW_SEARCH”.
MSWINSCK.OCX and ZGW_SEARCH.exe under EDIABAS \ Hardware \ ENET



Error Fehler 2: Net-0012: NO CONNECTION



13-10
Here is to check whether the ZGW is really connected to the Ethernet (via DHCP server), whether it
is turned on or it is the required entries i. d. EDIABAS.ini (see above) again to check / correct.



https://www.deviantart.com/obd2tools/journal/How-to-Resolve-BMW-ICOM-ISTAD-license-expired-Erro-756375477

MOPAR MicroPod II

2018-07-15 22:40:48 | 日記




12-0


Good things come in small packages, like Chrysler’s latest and
greatest diagnostic interface. This dongle-style device is the same
diagnostic and programming tool the dealerships are using. It offers 100
percent CAN coverage for Chrysler, Dodge,Jeep and Fiat vehicle
platforms. It replaces your StarMobile, StarScan, and witech Micropod 2.


12-1


Includes:
MicroPod II, USB MicroPod II connector
cable, wi-TECH Application Software and carrying case.


MOPAR MicroPod II Features:
* Supports all the latest technologies and vehicle platforms including the latest Chrysler/Fiat vehicles.
* Works as a direct replacement for the wiTECH VCI pod.
* No Smart cables required.
12-2


MicroPod II + Tablet
wiTECH 2 introduces fully wireless usage of your MicroPOD II with iOS or
Android tablets and phones! wiTECH 2.0 allows wireless connectivity
through any device with a web browser!


12-3


MicroPOD II Remote Trigger
The MicroPod II Trigger allows the technician to use the MicroPod’s
Flight Recorder capabilities. This trigger is used to start and stop
recording of a customized template which is set up using the wiTECH
Diagnostic Application.


12-4
wiTECH 2.0 diagnostic software is the state of the art diagnostic system
for Dodge, Chrysler, Jeep and North American Fiat vehicles. Professional Diagnostic Tool wiTECH 2.0 allows fully wireless connectivity to perform diagnostics, reprogramming and security functions.


Any mobile device with a browser will run the software, including
Android and iOS phones and tablets. A Mopar Tech Authority account is
required, as well as a secured MicroPod II.


This tool is used for a variety of model years but is required for all vehicles utilizing CAN operations.


The list to the right shows some of the many functions of OBD2 Scanner wiTECH 2.0.


*Increased speed
*Enhanced wireless security
*Full wireless operation
*No cables required
*Enables mobile devices
*Rapid device recovery
*No PC required
*More reliable ECU reprogramming
*Automatic WiFi reconnection
*Automated Flash recovery


12-5


12-6


12-7 12-8




Cat® Electronic Technician Maintain Productivity and Control Cost

2018-07-07 23:14:10 | 日記

40-1


Quickly reduce engine and machine downtime, control costs and schedule repairs more efficiently by


diagnosing problems using Cat Electronic Technician (ET).


Cat ET is easy to use. The software accesses information from the electronic control modules on Cat


engines and equipment. Using Cat ET, technicians can view status parameters, logged codes, active codes,


perform functional tests, and record and view data logs of equipment operation.


Optimize Profitability


•    View active and logged diagnostic codes to quickly identify faulty sensors.
•    Review logged event codes to show engine overspeeds, high temperatures, and more.
•    Monitor fuel consumption.
•    Perform diagnostic tests to quickly identify the root cause of problems.
•    Calibrate key components to ensure maximum operating efficiency.
•    Use Data Logger to record real-time data.
•    View previously recorded data logs to monitor trends in the health of your equipment to ensure


peak performance.


40-2
40-3
40-4


Maximize Efficiency


•    Search help options to guide every task.
•    Retrieve engine data quickly for fuel used, miles traveled, idle time and hours operated.
•    Display status of engine speed, throttle position, timing advance, fuel flow and more.
•    Check an electronic control module’s configuration and change user settings.


http://avdicommander.com/2018/06/25/cat-electronic-technician-maintain-productivity-and-control-cost/