1.Which tool can be used to force a reboot of a SWAN/SWAN 2 CLIP?
A.WANDUMP
B.WANFBT
C.WANLNCK
D.WANTCB
Correct:B
2.Which components can you install on the system console using the OSM Installer DVD ? (Select
two.)
A.Event Viewer
B.Low Level Link
C.Notification Director
D.Service Connection
Correct:B C
3.When replacing a PMF, within how much time must the power cable be reconnected?
A.15 seconds
B.20 seconds
C.25 seconds
D.30 seconds
Correct:C
4.What is used to replace a SWAN/SWAN2 concentrator?
A.WAN Wizard PRO
B.Guided Procedures
C.SCF
D.SP Tool
Correct:C
5.The SP Tool has identified a faulty X fabric cable between enclosure 1 and enclosure 3. Which
connector on the SEB in enclosure 1 is affected?
A.1
B.2
C.3
D.4
Correct:B
6.Using the HP suggested naming convention, identify the G4SA group, module, slot and port
number of LIF L112E.
A.GRP-11, MOD-2, SLOT-2, PORT-E
B.GRP-112, MOD-2, SLOT-2, PORT-E
C.GRP-11, MOD-2,SLOT-2, PORT-A
D.GRP-112, MOD-2, SLOT-2, PORT-A
Correct:C
7.Which action is required before replacing an X Fabric fiber-optic cable between MSEB and
Switch-to-Node ports?
A.Verify that internal Y fabric for all other nodes are fully operational.
B.Verify that external Y fabric for all other nodes are fully operational.
C.Verify that both internal and external Y fabric for all other nodes are fully operational.
D.Verify that both external X and Y fabric for all other nodes are fully operational.
Correct:C
8.Which preventive maintenance tasks are performed on an S-series server? (Select two.)
A.testing the fiber optic cables
B.cleaning tape drives regularly
C.running diagnostics on all devices
D.dusting or cleaning enclosures as needed
E.running traces on all communication lines
Correct:B D
9.To display all of the Fiber Channel Disks installed on the system along with their path states,
what step(s) must be taken from the OSM Service Connection?
A.Click the Logical Status icon, logon using the pop-up window, and then click on the FC Disk resource
type.
B.Click the Display icon and then choose the Attributes menu selection.
C.Click the Summary icon and then choose the Connection Status menu selection.
D.Click the Tools icon and then choose the Physical Configuration Tool menu selection.
Correct:A
10.To view the entire hardware inventory of the system, what steps must be taken?
A.Select the system item in the hierarchical view, and then use the display Menu attributes item.
B.Right-click on the system item in the hierarchical view, and then select the httributes sub-menu item.
C.Double-click on the system item in the hierarchical view.
D.Select the system item in the hierarchical view, and then change the view from physical to nventory.
Correct:D